330 research outputs found

    Collapse of superconductivity in cuprates via ultrafast quenching of phase coherence

    Get PDF
    The possibility of driving phase transitions in low-density condensates through the loss of phase coherence alone has far-reaching implications for the study of quantum phases of matter. This has inspired the development of tools to control and explore the collective properties of condensate phases via phase fluctuations. Electrically-gated oxide interfaces, ultracold Fermi atoms, and cuprate superconductors, which are characterized by an intrinsically small phase-stiffness, are paradigmatic examples where these tools are having a dramatic impact. Here we use light pulses shorter than the internal thermalization time to drive and probe the phase fragility of the Bi2_2Sr2_2CaCu2_2O8+ÎŽ_{8+\delta} cuprate superconductor, completely melting the superconducting condensate without affecting the pairing strength. The resulting ultrafast dynamics of phase fluctuations and charge excitations are captured and disentangled by time-resolved photoemission spectroscopy. This work demonstrates the dominant role of phase coherence in the superconductor-to-normal state phase transition and offers a benchmark for non-equilibrium spectroscopic investigations of the cuprate phase diagram.Comment: 24 pages, 9 figures, Main Text and Supplementary Informatio

    Natural Occurrence of Ochratoxin A in Blood and Milk Samples from Jennies and Their Foals after Delivery

    Get PDF
    An assessment of the natural ochratoxin A (OTA) exposure of seven Martina Franca jennies was carried out by analyzing blood and milk samples collected close to and after delivery. A total of 41 and 34 blood samples were collected from jennies and foals, respectively, and analyzed by ELISA. A total of 33 milk samples were collected from jennies and analyzed by the HPLC/FLD method based on IAC clean-up. Furthermore, 53 feed samples were collected from January to September and analyzed by a reference method (AOAC Official Method No. 2000.03) for OTA content. Feed samples showed OTA levels up to 2.7 ng/g with an incidence of 32%, while the OTA incidence rate in jennies' blood samples was 73%, with a median value of 97 ng/L and concentrations ranging fro

    Inflammatory role of extracellular sphingolipids in Cystic Fibrosis

    Get PDF
    Ceramide is emerging as one of the players of inflammation in lung diseases. However, data on its inflammatory role in Cystic Fibrosis (CF) as part of the extracellular machinery driven by lung mesenchymal stem cells (MSCs)-derived extracellular vesicles (EVs) are missing. We obtained an in vitro model of CF-MSC by treating control human lung MSCs with a specific CFTR inhibitor. We characterized EVs populations derived from MSCs (ctr EVs) and CF-MSCs (CF-EVs) and analyzed their sphingolipid profile by LC-MS/MS. To evaluate their immunomodulatory function, we treated an in vitro human model of CF, with both EVs populations. Our data show that the two EVs populations differ for the average size, amount, and rate of uptake. CF-EVs display higher ceramide and dihydroceramide accumulation as compared to control EVs, suggesting the involvement of the de novo biosynthesis pathway in the parental CF-MSCs. Higher sphingomyelinase activity in CF-MSCs, driven by inflammation-induced ceramide accumulation, sustains the exocytosis of vesicles that export new formed pro-inflammatory ceramide. Our results suggest that CFTR dysfunction associates with an enhanced sphingolipid metabolism leading to the release of EVs that export the excess of pro-inflammatory Cer to the recipient cells, thus contributing to maintain the unresolved inflammatory status of CF

    A Method of Drusen Measurement Based on the Geometry of Fundus Reflectance

    Get PDF
    BACKGROUND: The hallmarks of age-related macular degeneration, the leading cause of blindness in the developed world, are the subretinal deposits known as drusen. Drusen identification and measurement play a key role in clinical studies of this disease. Current manual methods of drusen measurement are laborious and subjective. Our purpose was to expedite clinical research with an accurate, reliable digital method. METHODS: An interactive semi-automated procedure was developed to level the macular background reflectance for the purpose of morphometric analysis of drusen. 12 color fundus photographs of patients with age-related macular degeneration and drusen were analyzed. After digitizing the photographs, the underlying background pattern in the green channel was leveled by an algorithm based on the elliptically concentric geometry of the reflectance in the normal macula: the gray scale values of all structures within defined elliptical boundaries were raised sequentially until a uniform background was obtained. Segmentation of drusen and area measurements in the central and middle subfields (1000 ÎŒm and 3000 ÎŒm diameters) were performed by uniform thresholds. Two observers using this interactive semi-automated software measured each image digitally. The mean digital measurements were compared to independent stereo fundus gradings by two expert graders (stereo Grader 1 estimated the drusen percentage in each of the 24 regions as falling into one of four standard broad ranges; stereo Grader 2 estimated drusen percentages in 1% to 5% intervals). RESULTS: The mean digital area measurements had a median standard deviation of 1.9%. The mean digital area measurements agreed with stereo Grader 1 in 22/24 cases. The 95% limits of agreement between the mean digital area measurements and the more precise stereo gradings of Grader 2 were -6.4 % to +6.8 % in the central subfield and -6.0 % to +4.5 % in the middle subfield. The mean absolute differences between the digital and stereo gradings 2 were 2.8 +/- 3.4% in the central subfield and 2.2 +/- 2.7% in the middle subfield. CONCLUSIONS: Semi-automated, supervised drusen measurements may be done reproducibly and accurately with adaptations of commercial software. This technique for macular image analysis has potential for use in clinical research

    MEK1/2 regulate normal BCR and ABL1 tumor-suppressor functions to dictate ATO response in TKI-resistant Ph+ leukemia

    Get PDF
    Resistance to tyrosine kinase inhibitors (TKIs) remains a clinical challenge in Ph-positive variants of chronic myeloid leukemia. We provide mechanistic insights into a previously undisclosed MEK1/2/BCR::ABL1/BCR/ABL1-driven signaling loop that may determine the efficacy of arsenic trioxide (ATO) in TKI-resistant leukemic patients. We find that activated MEK1/2 assemble into a pentameric complex with BCR::ABL1, BCR and ABL1 to induce phosphorylation of BCR and BCR::ABL1 at Tyr360 and Tyr177, and ABL1, at Thr735 and Tyr412 residues thus provoking loss of BCR's tumor-suppression functions, enhanced oncogenic activity of BCR::ABL1, cytoplasmic retention of ABL1 and consequently drug resistance. Coherently, pharmacological blockade of MEK1/2 induces dissociation of the pentameric MEK1/2/BCR::ABL1/BCR/ABL1 complex and causes a concurrent BCRY360/Y177, BCR::ABL1(Y360/Y177) and cytoplasmic ABL1(Y412/T735) dephosphorylation thereby provoking the rescue of the BCR's anti-oncogenic activities, nuclear accumulation of ABL1 with tumor-suppressive functions and consequently, growth inhibition of the leukemic cells and an ATO sensitization via BCR-MYC and ABL1-p73 signaling axes activation. Additionally, the allosteric activation of nuclear ABL1 was consistently found to enhance the anti-leukemic effects of the MEK1/2 inhibitor Mirdametinib, which when combined with ATO, significantly prolonged the survival of mice bearing BCR::ABL1-T315I-induced leukemia. These findings highlight the therapeutic potential of MEK1/2-inhibitors/ATO combination for the treatment of TKI-resistant leukemia

    Benefit of an electronic head‐mounted low vision aid

    Get PDF
    Purpose: To evaluate the efficacy of electronic head-mounted low vision aid (e-LVA) SightPlus (GiveVision, UK, givevision.net) and to determine which people with low vision would see themselves likely using an e-LVA like this. Methods: Sixty participants with low vision aged 18 to 93 used SightPlus during an in-clinic study session based on a mixed methods design. Visual acuity (ETDRS), contrast sensitivity (Pelli-Robson) and reading performance (MNREAD) were measured binocularly at baseline (no device), with the device in ‘normal’ mode (zoom only), and with preferred enhanced mode (zoom and one of four digital image enhancements). At the end of the session, a short questionnaire recorded willingness to use an e-LVA like SightPlus, potential use cases, positive/negative comments and adverse effects. Results: Binocular distance visual acuity improved significantly by 0.63 logMAR on average (p < 0.0001) to 0.20 logMAR. Contrast sensitivity improved significantly by 0.22 log units (p < 0.0001) to 1.21 log units with zoom only and by 0.40 log units to 1.37 log units with zoom and preferred image enhancement. Reading performance improved significantly for near visual acuity and critical print size (p < 0.015), although reading speed significantly decreased (p < 0.0001). Nearly half (47%) of the participants indicated they would use an e-LVA like SightPlus, especially for television, reading and entertainment (e.g. theatre). Multivariate logistic regression showed that proportion of lifetime affected by sight loss, baseline contrast sensitivity and use of electronic LVAs explained 41% of the variation in willingness to use. Conclusions: SightPlus improves visual function in people with low vision and would be used in its current form by one half of the people who tried it. Adverse effects were infrequent and resolved when the device was removed. Future work should focus on comparing e-LVAs through repeatable real-world tasks and impact on quality of life
    • 

    corecore